ORIGINAL ARTICLE
Year : 2017  |  Volume : 32  |  Issue : 2  |  Page : 89-92  

Estimation of whole body radiation exposure to nuclear medicine personnel during synthesis of 177lutetium-labeled radiopharmaceuticals


Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India

Date of Web Publication16-Mar-2017

Correspondence Address:
Dr. Nishikant Avinash Damle
Assistant Professor, Department of Nuclear Medicine, AIIMS, New Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-3919.202245

Rights and Permissions
   Abstract 

Purpose of the Study: With rapid development in the field of nuclear medicine therapy, radiation safety of the personnel involved in synthesis of radiopharmaceuticals has become imperative. Few studies have been done on estimating the radiation exposure of personnel involved in the radio labeling of 177Lu-compounds in western countries. However, data from the Indian subcontinent are limited. We have estimated whole body radiation exposure to the radiopharmacist involved in the labeling of: 177Lu-DOTATATE, 177Lu-PSMA-617, and 177Lu-EDTMP. Materials and Methods: Background radiation was measured by keeping a pocket dosimeter around the workbench when no radioactive work was conducted. The same pocket dosimeter was given to the radiopharmacist performing the labeling of 177Lu-compounds. All radiopharmaceuticals were synthesized by the same radiopharmacist with 3, 1 and 3 year experience, respectively, in radiolabeling the above compounds. Results: One Curie (1 Ci) of 177Lu was received fortnightly by our department. Data were collected for 12 syntheses of 177Lu-DOTATATE, 8 syntheses of 177Lu-PSMA-617, and 3 syntheses of 177Lu-EDTMP. Mean time required to complete the synthesis was 0.81, 0.65, and 0.58 h, respectively. Mean whole body radiation exposure was 0.023 ± 0.01 mSv, 0.01 ± 0.002 mSv, and 0.002 ± 0.0006 mSv, respectively. Overall mean radiation dose for all the three 177Lu-compounds was 0.014 mSv. Highest exposure was obtained during the synthesis of 177Lu-DOTATATE. Conclusion: Our data suggest that the manual radiolabeling of 177Lu compounds is safe, and the whole body radiation exposure to the involved personnel is well within prescribed limits.

Keywords: Personnel dosimetry, manual radiolabeling, radionuclide therapy


How to cite this article:
Arora G, Mishra R, Kumar P, Yadav M, Ballal S, Bal C, Damle NA. Estimation of whole body radiation exposure to nuclear medicine personnel during synthesis of 177lutetium-labeled radiopharmaceuticals. Indian J Nucl Med 2017;32:89-92

How to cite this URL:
Arora G, Mishra R, Kumar P, Yadav M, Ballal S, Bal C, Damle NA. Estimation of whole body radiation exposure to nuclear medicine personnel during synthesis of 177lutetium-labeled radiopharmaceuticals. Indian J Nucl Med [serial online] 2017 [cited 2023 Mar 20];32:89-92. Available from: https://www.ijnm.in/text.asp?2017/32/2/89/202245


   Introduction Top


Personnel monitoring is an intergral part of any radiation safety program. Personnel monitoring aims to keep the occupational radiation exposure as low as reasonably achievable (ALARA) and is based on the principle that the benefits of any intentional or planned exposure to radiation should outweigh the resultant detriment that could arise.[1] Safe radiation work practices and permissible radiation exposure limits have been laid by various national and international regulatory authorities.

As per ICRP recommendations 103 (2007), the equivalent radiation dose to personnel should not exceed 20 mSv/year averaged over 5 years, not exceeding 50 mSv in any year.[2] These limits are aimed at keeping the probability of stochastic effects of radiation to the lowest, while avoiding the occurrence of non-stochastic effects altogether. By defination, any person handling radiation and likely to receive an occupational radiation exposure of more than 1 mSv is liable to be monitored.

In nuclear medicine, personnel involved in synthesis of radiopharmaceuticals, dose administration, and/or scan acquisition are most likely to receive radiation exposure. The risk could be even higher while handling therapeutic radiopharmaceuticals. In the present study, we have focussed on the personnel involved in synthesis of radiopharmaceuticals involving Lu-177 that is DOTATATE/DOTANOC, PSMA-617 and EDTMP. The choice of radiopharmaceuticals was based on the fact that these three radiopharmaceuticals are being routinely synthesized at our department, at the All India Institute of Medical Sciences, New Delhi, India.

Over the last decade, Lu-177 has become the radionuclide of choice for various radionuclide therapy procedures owing to its ease of large-scale production in moderate flux reactors, favorable radiation characteristics enabling imaging along with therapy (β-max: 497 keV; γ1: 113 keV; 6.4% and γ2: 208 keV; 11%); and sufficiently long half-life (6.7 days) allowing easy transport to centers far off from a reactor site.[3] These economic, characteristic, and logistic advantages of Lu-177 have become even more significant in developing countries, where affordable therapeutic options are always sought.

Although there is a plethora of literature on the internal dosimetry or patient dosimetry with 177Lu-radiopharmceuticals, there is a lesser literature on the personnel dosimetry, especially those involved in synthesis. 177Lu-DOATATATE/DOTANOC, PSMA-617, and EDTMP can be synthesized in automatic or semi-automatic chemistry modules or by manual methods. Since a manual method is more cost effective than automatic or semi-automatic methods, it is the most widely practiced method in developing countries like India. However, it poses a risk of comparatively higher radiation exposure to the personnel involved. Therefore, the present study aims to monitor the radiation dose levels to personnel during manual synthesis of 177Lu-labeled compounds (DOTATATE/DOTANOC, PSMA-617, and EDTMP) and reviews work practices that may reduce the radiation exposure.


   Materials and Methods Top


Lu-177 as LuCl3 was procured from BRIT, Mumbai, India. A digital pocket dosimeter (MyDose Mini) was obtained from ALOKA. The precursors used in the synthesis of 177Lu-labeled DOTATATE/DOTANOC and PSMA-617 were obtained from ABX GmbH, Germany, and EDTMP kit was obtained from BRIT/Polatom. All other reagents used in labeling were of analytical grade.

Procedure

Synthesis of Lu-177-labeled DOTATATE, PSMA-617, and EDTMP was carried out by designated skilled personnel at the radio-pharmacy laboratory of the Department of Nuclear Medicine, AIIMS, New Delhi, India. These radiopharmaceuticals were routinely synthesized in our department, on fortnightly basis by manual methods. DOTATATE and DOTANOC were labeled alternatively depending on the availability of precursor. The MyDose mini radiation pocket dosimeter was used to measure the radiation exposure. Initially, background radiation of the laboratory, where labeling was carried out, was measured by placing the dosimeter in the laboratory when no radioactive work was being conducted. The background exposure readings were taken at different places around the labeling workbench and mean was calculated.

Personnel were issued a pocket dosimeter prior to the start of labeling procedure. Initial reading of the meter was set at zero every time. Radiation exposure readings recorded in the meter were noted on the completion of labeling process. The total amount of radioactivity handled during labeling and the duration of each labeling procedure were noted.

Statistical Analysis

Descriptive statistic analysis was done for the collected data; and mean, median, standard deviation (SD), and range (minimum to maximum value) were determined. All the readings were expressed as mean ± SD.


   Results Top


A total of 23 readings of radiation exposure were obtained during the labeling of all 177Lu-radiopharmaceuticals put together. [Table 1] shows the number of readings obtained for individual radiopharmaceuticals. Background radiation exposure reading was observed to be zero (for 1 hour) around the labeling workbench when no radioactive work was being conducted.
Table 1: Number of readings of exposure of various radiopharmaceuticals

Click here to view


The details of radiation dose during labeling of 177Lu-DOTATATE/NOC, PSMA-617, and EDTMP are given in [Table 2], [Table 3], and [Table 4], respectively. [Figure 1] represents the trend of radiation exposure during labeling of the three radiopharmaceuticals.
Table 2: Radiation exposure during the labeling of 177Lu-DOTATATE/NOC

Click here to view
Table 3: Radiation exposure during the labeling of 177Lu-PSMA-617

Click here to view
Table 4: Radiation exposure during the labeling of 177Lu-EDTMPS


Click here to view
Figure 1: Radiation dose of 177Lu labeled DOTATATE/NOC (series 1), PSMA-617 (series 2) and EDTMP (series 3) with the standard error

Click here to view


The mean radiation dose recorded in 177Lu-DOTATATE/NOC labeling was 0.023 ± 0.01 mSv, 177Lu-PSMA-617 was 0.01±0.002, mSv and 177Lu-EDTMP was 0.002 ± 0.0006 mSv and the mean duration of labeling was 0.81, 0.65, and 0.58 h, respectively. The specific activity of Lu-177 was ~19–22 mCi/µgm in all labeling procedures.

The mean estimated radiation dose rate during the three labeling procedures was 0.03 ± 0.01 mSv/h for DOTATATE/NOC, 0.01 ± 0.003 mSv/h for PSMA-617, and 0.003 ± 0.001 mSv/h for EDTMP. Overall mean radiation dose was 0.014 mSv and duration was 0.72 h.


   Discussion Top


The objective of the study was to evaluate the radiation dose levels to personnel involved in the labeling of 177Lu-labeled radiopharmaceuticals that is DOTATATE/NOC, PSMA-617, and EDTMP. The method of labeling these compounds with Lu-177 may be automated/semi-automated[4],[5] or manual. At our department, we perform routine radiolabeling of these compounds with Lu-177 by a manual method, as it is more cost effective and automated modules are not available to us at present. However, in manual labeling procedures, the radiation safety concerns are higher than that in automated or semi-automated methods.

Labeling of 177Lu-DOTATATE/NOC was performed as per the method described by Das et al.[6] and that of 177Lu-PSMA-617 was performed by the method described by Ahmadzadehfar et al.[7] Automated or semi-automated modules are not available for the labeling of 177Lu-EDTMP, as it is a single step procedure that involves simple addition and incubation of the EDTMP.[8]

Our results suggest that the labeling of 177Lu-DOTATATE/NOC yielded the highest mean radiation dose of 0.023 ± 0.01 mSv, followed by 177Lu-PSMA-617 0.01 ± 0.002 mSv, whereas the dose from the labeling of 177Lu-EDTMP was the lowest 0.002 ± 0.0006 mSv. The reason for the observed trend is the time of radiolabeling, higher the duration of radioactivity handling, higher the radiation exposure. Overall dose trend also follows the same order as can be seen in [Figure 1].

One of the most important factors that may affect the radiation dose to personnel in manual methods of radiolabeling is the skill. Different radiation workers have different levels of proficiency and expertise in the handling of radioisotopes that cause the readings to vary greatly among personnel. In our study, we ensured that every time the same radiation worker was involved in the radiolabeling of a particular compound to minimize such inter-personnel variations. However, intra-personnel variations still exist. Furthermore, to maintain uniformity of measurements and minimize the errors, the pocket dosimeter assigned to particular personnel during labeling was kept the same. It was also ensured that through out the observation period (labeling process), the personnel do not carry out any other radiation work or go to any other radiation area that might yield erroneously high reading on the dosimeter.

Other factors that might affect radiation dose are the duration and amount of radioactivity handled during the labeling procedure. Both, radioactivity and mean duration are highest for DOTATATE/NOC (896 mCi; 0.81 h), followed by PSMA-617 (190 mCi; 0.65 h), and EDTMP (57 mCi; 0.58 h) in our study. This explains the trend of radiation dose for the three procedures.

Overall mean radiation dose for all the three 177Lu-compounds was 0.014 mSv. Our department has a high throughput of patients, and synthesis of 177Lu-compounds is performed once every fortnight, provided there is timely availability of Lu-177 and precursors. Assuming 24 such synthesis every year, the total mean dose to the personnel involved will be ~0.34 mSv. This dose level is far less than the stipulated limit of 20 mSv. Even if in future the synthesis rate increases to once per day and the same radiopharmacist is involved in synthesis, the dose will be ~5.26 mSv. The background activity in the radiolabelling laboratory returned to that existed pre-labeling, that is, zero (for 1 hour) after proper disposal of radioactive vials, syringes, absorbent sheets, gloves, and other contaminated waste. These things were properly sealed, labeled, and stored in a waste disposal room for decay. The reading of the TLD badge of the personnel involved was also within prescribed limits, that is, 0.9 mSv for chest badge for 1 year. It should be noted that this reading includes the radiation expsure to the presonnel from other sources as well apart from the radiolabeling procedures mentioned in this study as the personnel was involved in other departmental work also. This shows that even the manual radio-labeling methods of Lu-177 compounds are safe, provided safe work practices are followed.

The dose can be further reduced by involving staff well trained in good radio-pharmacy practices and radiation safety. Though the procedures are safe even if a single trained staff member conducts all the synthesis, it would be preferable to involve minimum two trained personnel to share and further reduce the radiation burden. The regular use of radiation monitoring devices such as the pocket dosimeters and TLD badges should be encouraged, and radiation surveys should be routinely conducted.

The study was conducted over a period of 6 months and various logistic reasons such as unexpected delay in delivery of Lu-177, or precursors sometimes restricted the regular synthesis of 177Lu-compounds at our department. Hence, not much data points could be collected that is a major limitation of the study. Furthermore, due to unavailability of automated/semi-automated chemistry modules at our department a direct comparison was not possible. However, despite a less number of observations, the study is significant as there are only few similar studies on radiation dose levels to personnel involved in Lu-177 radio-labeling.


   Conclusion Top


Our data suggest that the manual radio-labeling of 177Lu-compounds is safe and the whole body radiation exposure to the involved personnel is well within the prescribed limits of ICRP, i.e., 20 mSv/year (averaged over 5 years). However, the exposure can further be reduced using semi-automated and automated modules, wherever possible.

Financial support and sponsorship

Nil

Conflicts of interest

There are no conflicts of interest[8]

 
   References Top

1.
International basic safety standards for protection against ionizing radiation and for the safety of radiation sources. IAEA, Vienna, Austria. Basic safety standards series no. 115.  Back to cited text no. 1
    
2.
The 2007 Recommendations of the International Commission on Radiological Protection. Annals of the ICRP, publication 103.   Back to cited text no. 2
    
3.
Pillai MR, Chakraborty S, Das T, Venkatesh M, Ramamoorthy N. Production logistics of 177Lu for radionuclide therapy. Appl Radiat Isot 2003;59:109-18.  Back to cited text no. 3
    
4.
Aslani A, Snowdon GM, Bailey DL, Schembri GP, Bailey EA, Pavlakis N, Roach PJ. Lutetium-177 DOTATATE production with an automated radiopharmaceutical synthesis system. Asia Ocean J Nucl Med Biol 2015;3:107-15.  Back to cited text no. 4
    
5.
Decristoforo C, Summer D, Wurzer A, Haubner R, Virgolini I, Guggenberg EV. Validation of a cassette based fully automated synthesis of 177Lu-PSMA617. World J Nucl Med 2015;14:S3-7.  Back to cited text no. 5
    
6.
Das T, Chakraborty S, Kallur KG, Venkatesh M, Banerjee S. Preparation of patient doses of (177)Lu-DOTA-TATE using indigenously produced (177)Lu: The Indian experience. Cancer Biother Radiopharm 2011;26:395-400.  Back to cited text no. 6
    
7.
Ahmadzadehfar H, Rahbar K, Kürpig S, Bögemann M, Claesener M, Eppard E, Gärtner F, Rogenhofer S, Schäfers M, Essler M. Early side effects and first results of radioligand therapy with 177Lu-DKFZ-617 PSMA of castrate-resistant metastatic prostate cancer: a two-centre study. EJNMMI Res 2015;5:36.  Back to cited text no. 7
    
8.
Agarwal KK, Singla S, Arora G, Bal C. (177) Lu-EDTMP for palliation of pain from bone metastases in patients with prostate and breast cancer: A phase II study 2015. Eur J Nucl Med Mol Imaging 2015;42:79-88.  Back to cited text no. 8
    


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4]


This article has been cited by
1 Radiation Exposure to the Nuclear Medicine Personnel During Preparation and Handling of 213Bi-Radiopharmaceuticals
Parul Thakral, Ishita Sen, Jakub Simecek, Sebastian Marx, Jyotsna Kumari, Sunil Kumar, Pankaj Tandon, Sugandha Dureja, Vineet Pant
Journal of Nuclear Medicine Technology. 2020; 48(1): 68
[Pubmed] | [DOI]



 

Top
  
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed2822    
    Printed74    
    Emailed0    
    PDF Downloaded314    
    Comments [Add]    
    Cited by others 1    

Recommend this journal