Indian Journal of Nuclear Medicine
Home | About IJNM | Search | Current Issue | Past Issues | Instructions | Ahead of Print | Online submissionLogin 
Indian Journal of Nuclear Medicine
  Editorial Board | Subscribe | Advertise | Contact
Users Online: 262 Print this page  Email this page Small font size Default font size Increase font size
ORIGINAL ARTICLE
Year : 2018  |  Volume : 33  |  Issue : 1  |  Page : 43-47

Dacroscintigraphy by pediatric dropper technique: A user-friendly instillation procedure of radiotracer


1 Departments of Nuclear Medicine, Army Hospital R and R, New Delhi, India
2 PET Scan Center and Cyclotron facility Army Hospital R and R, New Delhi, India
3 Department of Opthalmology, Base hospital Delhi Cantt, New Delhi, India

Correspondence Address:
Dr. Anurag Jain
Army Hospital R and R, New Delhi - 110 010
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijnm.IJNM_98_17

Rights and Permissions

Context: Instillation or application of the radiotracer over the tear film is one of the important parts of dacroscintigraphy. Our study explains the value of an improvised dropper technique so that desired amount of radioactivity in desired volume can be instilled over the tear film. Aim: The aim of the study is to introduce a simple and convenient instillation method based on dropper technique for performing dacroscintigraphy. This improvised dropper technique can be used so that desired amount of radioactivity in desired volume can be instilled over the tear film. The objectives of this experiment are to measure the volume and activity of each drop from the dropper. Settings and Design: Experiment of volume and activity measurement standardization was carried out in two parts. In the first part, we calculated the volume of each drop indirectly to standardize the volume of drop. In the second part, we standardized the activity in each drop by measuring it in a dose calibrator. Subjects and Methods: In this study, we used a common pediatric dropper of approximately 1 ml capacity, radioactivity (99mTcO4 pertechnetate), sample vial (container), vial holder, a pair of nonsterile gloves, dose calibrator, etc., Experiments of volume and radioactivity standardization were carried out in two parts. The first part of experiment calculated volume of each drop indirectly, and in the second, we standardized the activity in each drop by measuring it in dose calibrator. Statistical analysis used: Analysis of variance test was used to calculate the correlation of readings by same individual as well as among the three individuals Results: After analysis of result obtained, it was understood that there was no significant difference found in volume and activity of each drop in the readings recorded by same individual as well as among the three individuals. The calculated activity and observed activity were 86.64 and 79.16 μCi, respectively. The difference was only 8.63% lying within acceptable limits.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed310    
    Printed4    
    Emailed0    
    PDF Downloaded61    
    Comments [Add]    

Recommend this journal