Indian Journal of Nuclear Medicine
Home | About IJNM | Search | Current Issue | Past Issues | Instructions | Ahead of Print | Online submissionLogin 
Indian Journal of Nuclear Medicine
  Editorial Board | Subscribe | Advertise | Contact
Users Online: 88 Print this page  Email this page Small font size Default font size Increase font size
ORIGINAL ARTICLE
Year : 2017  |  Volume : 32  |  Issue : 4  |  Page : 279-282

Calculating gamma camera uniformity parameters: Beyond the vendor-specific protocol


1 Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India
2 Department of Computer Science, SGTB Khalsa College, University of Delhi, New Delhi, India

Correspondence Address:
Anil Kumar Pandey
Department of Nuclear Medicine, All India Institute of Medical sciences, Ansari Nagar, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijnm.IJNM_67_17

Rights and Permissions

Objectives: The aim of this study was to develop and verify a personal computer-based software tool for calculating uniformity indices of gamma camera. Materials and Methods: The program was developed in MATLAB R2013b under Microsoft Windows operating system. Noise-less digital phantoms with known uniformity parameters were used to verify the accuracy of the program. Two hundred and forty-four Co-57 flood source images were acquired on Symbia T6 and Discovery nuclear medicine/computed tomography 670. The uniformity indices of these images were determined with their respective vendor's software and also by the tool developed. Bland–Altman plots were used for measuring the agreements between the developed program and the vendor's program for the calculation of uniformity indices. Results: The tool for calculating uniformity indices was found to be accurate. Uniformity indices measured with the tool revealed a very good correlation with vendor's software based on Bland–Altman analysis, as almost all measurements were within the ±2 standard deviation range. Conclusion: The software tool for calculation of uniformity indices is accurate, and the uniformity indices calculated by it are in agreement with uniformity indices calculated by the vendor's software.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed36    
    Printed4    
    Emailed0    
    PDF Downloaded10    
    Comments [Add]    

Recommend this journal