Indian Journal of Nuclear Medicine
Home | About IJNM | Search | Current Issue | Past Issues | Instructions | Ahead of Print | Online submissionLogin 
Indian Journal of Nuclear Medicine
  Editorial Board | Subscribe | Advertise | Contact
Users Online: 152 Print this page  Email this page Small font size Default font size Increase font size
ORIGINAL ARTICLE
Year : 2017  |  Volume : 32  |  Issue : 2  |  Page : 89-92

Estimation of whole body radiation exposure to nuclear medicine personnel during synthesis of 177lutetium-labeled radiopharmaceuticals


Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Nishikant Avinash Damle
Assistant Professor, Department of Nuclear Medicine, AIIMS, New Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-3919.202245

Rights and Permissions

Purpose of the Study: With rapid development in the field of nuclear medicine therapy, radiation safety of the personnel involved in synthesis of radiopharmaceuticals has become imperative. Few studies have been done on estimating the radiation exposure of personnel involved in the radio labeling of 177Lu-compounds in western countries. However, data from the Indian subcontinent are limited. We have estimated whole body radiation exposure to the radiopharmacist involved in the labeling of: 177Lu-DOTATATE, 177Lu-PSMA-617, and 177Lu-EDTMP. Materials and Methods: Background radiation was measured by keeping a pocket dosimeter around the workbench when no radioactive work was conducted. The same pocket dosimeter was given to the radiopharmacist performing the labeling of 177Lu-compounds. All radiopharmaceuticals were synthesized by the same radiopharmacist with 3, 1 and 3 year experience, respectively, in radiolabeling the above compounds. Results: One Curie (1 Ci) of 177Lu was received fortnightly by our department. Data were collected for 12 syntheses of 177Lu-DOTATATE, 8 syntheses of 177Lu-PSMA-617, and 3 syntheses of 177Lu-EDTMP. Mean time required to complete the synthesis was 0.81, 0.65, and 0.58 h, respectively. Mean whole body radiation exposure was 0.023 ± 0.01 mSv, 0.01 ± 0.002 mSv, and 0.002 ± 0.0006 mSv, respectively. Overall mean radiation dose for all the three 177Lu-compounds was 0.014 mSv. Highest exposure was obtained during the synthesis of 177Lu-DOTATATE. Conclusion: Our data suggest that the manual radiolabeling of 177Lu compounds is safe, and the whole body radiation exposure to the involved personnel is well within prescribed limits.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed78    
    Printed2    
    Emailed0    
    PDF Downloaded8    
    Comments [Add]    

Recommend this journal